SL EVO: Long-term Stability Engineered Into Every Reading
A second diaphragm continuously measures atmospheric pressure, fully sealed off from the condensation, moisture, dust, and buildup that cause conventional sensors to drift.
- Two coupled diaphragms and two RTD temperature sensors work in tandem for stable, accurate output
- Fully closed and hermetically sealed measurement cell with no direct contact to the atmosphere
- Integrated temperature compensation and tank linearization with direct output of volume, level or pressure, even for tanks with complex geometries

The Conventional Approach
Conventional sensors equalize atmospheric pressure through an open vent, creating a direct path for condensation, moisture, dust, and buildup.

The SL EVO Way: A Dual Diaphragm
The SL EVO replaces the traditional atmospheric vent with a sealed reference diaphragm, eliminating a common pathway for moisture ingress and condensation-related measurement drift.

Goodbye Drift
No more re-zeroing for humidity swings or condensation. The SL EVO holds its accuracy through the conditions that throw conventional sensors off.
- Built for any hygienic application, including outdoor tanks, cooling tanks, and other environments with significant temperature fluctuations
- Proven in applications like raw milk storage and beer maturation tanks
- Stays within ≤0.2% of URL for a full year, minimum


Hello Ease of Use
- New display with optimized readout in both vertical and horizontal orientations, angled 45° for visibility from any installation
- 360° signal indicator with LED ring light and color code, allowing you to see the sensor status (normal, warning, error) at a glance, even from across the room
- Quick, tool-free programming and field calibration with one-touch setup via capacitive buttons or IO-Link, and remote firmware upgrade with IO-Link
- Lower maintenance requirements reduce recalibration events, service visits, and production disruptions.
Built to Just Work
- Flex Hybrid Technology runs analog and digital communication in parallel — 4…20 mA, IO-Link, and HART 7.0, all available on one sensor
- Calibrated accuracy of 0.2% of URL, with temperature stability of ±0.2% per 5°C (10°F) and a 0.5-second response time
- Smart Replace Design: automatic configuration simply by plugging into the IO-Link Master